(1) Load adjustment rate (also known as current adjustment rate)
Under rated network voltage, the maximum relative change of output voltage is usually expressed as a percentage or sometimes as a pair of absolute changes when load current changes from zero to the maximum.
(2) Output resistance (also known as equivalent or internal resistance)
Under the rated voltage, output voltage due to changes in load current delta IL change delta Uo, the output resistance for Ro = | delta Uo/delta IL | Ω.